Description
Features
- A-Scan Files: Up to 512 files to save testing data including operation parameters plus A-scan. The stored data sets can be easily previewed, recalled and exported to a computer for editing and printing
- Thickness Files: Up to 10,000 thickness values stored in single thickness file
- PC Communication: Bi-directional RS232 or RS232-USB adaptor connected with PC
- DAC / TCG: DAC or TCG with a maximum of 16 reference echoes, 4 other curves can be displayed with variable dB intervals. DAC curves can be varied with variable dB or variable range
- AVG / DGS: DGS curves can be displayed automatically, DGS curves can be varied with variable dB or variable range
- Readings: Up to 26 selectable readings (Sound path, projection distance, depth, echo height and ERS.)
- B-Scan: Selectable corrosion-featured B-scan and full-featured B-scan
- Square Wave Pulser: Square wave pulsers allow optimum probe matching by adjusting pulse width and voltage. Difficult to penetrate metallic applications and especially non-metal inspection, like composite materials, are optimized. Pulse width is tunable up to 1000 ns in 10 ns steps. Pulser voltage is adjustable from 20 to 500 V in 10 V steps
- Rectification: Positive half-wave, negative half-wave, full-wave, RF
- Reject (suppression): 0 to 90% linear units inch, millimeter or microsecond selectable
- Languages: Selectable English, Chinese
- Gate Monitors: Two independent flaw gates controllable over entire sweep range
- Measurement Modes: Zero-to-first, multi-echo with selectable flank or peak detection
- TTL Output: Three independently assignable outputs, instantaneous, timed, latched with visual LED and audible horn alarms
- Alarm: Selectable positive logic, negative logic, upper limit thickness or lower limit thickness alarm mode
- Curved Surface Correction: Corrects sound path information when using an angle beam transducer to circumferentially inspect a curved surface for either tubular or bar inspections
- Auto Calibration: Measurement and setting of sound velocity and probe delay using two known calibration echoes (2-point calibration)
- Auto Gain: Automatically adjusts the system sensitivity to bring (increase or decrease) the measured echo to the suitable echo height. Echo height setting value from 10 % to 90 % of the screen height
- Display Screen: 5.7 inch LED backlight TFT_LCD
- Display Resolution: 320 x 240 pixels, selectable 4 scheme colours and 8 A-Scan colours
- A-Scan Resolution: Standard 200 x 220 pixels or 100 x 220 pixels
- Display Update: 150Hz
Specifications:
- Range: 1 to 10,000 mm at steel velocity, range selectable in fixed steps or continuously variable
- Material Velocity: Continuously adjustable from 100 to 20,000 m/s, 33 selectable material velocities
- Display Delay: -5 to 3400 µs in steel (dependent on range)
- Probe Delay (Zero Offset): 0 to 100 µs
- Damping: 50, 75, 150, 500 ohms
- Gain: 0 to 110 dB adjustable in selectable steps of 0.2, 0.5, 1, 2, 6 and 12dB. User definable, and locked
- Pulse Repetition Frequency: 20 to 1KHz
- Bandwidth: 0.2 to 20 MHz with 3 selectable broadbands
- A/D Sample Rate: 100MHz (Hardware Rate)
- Probe Connections: BNC / Lemo
- Power Adapter: 9VDC, 110-220VAC
- Battery Power 7.4V, 6600Ah, Lithium Ion Battery Pack
- Battery Life: 12 hours on Li-Ion Battery Pack
- Operating Temperature: -10 to 60℃
- Stored Temperature: -25 to 70℃
- Size: 266mm × 229mm × 56mm
- Weight: 2kg with Li-ion battery pack
- Horizontal Linearity Error: ≤0.1%
- Vertical Linearity Error: ≤3%
- Echoes Resolution: >30dB
- Sensitivity Margin: >60dB (200mm, Φ2, flat bottom hole)
- Dynamic Range: >30dB
Standard Package:
- Main Body
- Straight Beam Probe
- Angle Probe
- Machine-probe Cable
- Power Adapter (Charger)
- Battery
- Data proceeding Software
- USB communication cable
- Manual
- Instrument Case
- Guarantee Card
- Packing List